Driver Card No. CB-016S2 Driver Cards ITOH DENKI Vietnam | ITOH DENKI Việt Nam
Models Applicable
PM486FS, PM486FE, PM486FP,
PM570FE, PM605FE, PM635FS
PM570FE, PM605FE, PM635FS
The CB-016S2 driver card is used to control Power Moller® 24 brushless DC motorized rollers. It performs motor run/stop along with direction
functions. Speed selection via rotary switch (20 fixed speeds). Variable speed can also be controlled by an external analogue voltage
(0 to 10V). Overload protection through a built-in thermister and current limiter; error signal in case of motor overload, Switchable PNP or
NPN inputs / outputs. Acceleration and deceleration regulated using 2 potentiometers (0 Ã 2sec). Automatic or manual restart after overload
activation. The CB-016S2 can deliver a PWM (Pulse Width Modulation) by means of a magnetic pulse. Also available for rollers with built-in brakes, CB-016BS2.
functions. Speed selection via rotary switch (20 fixed speeds). Variable speed can also be controlled by an external analogue voltage
(0 to 10V). Overload protection through a built-in thermister and current limiter; error signal in case of motor overload, Switchable PNP or
NPN inputs / outputs. Acceleration and deceleration regulated using 2 potentiometers (0 Ã 2sec). Automatic or manual restart after overload
activation. The CB-016S2 can deliver a PWM (Pulse Width Modulation) by means of a magnetic pulse. Also available for rollers with built-in brakes, CB-016BS2.
Technical Document
![]() | CB-016S2 Technical Document PDF |
CAD Drawing Download (.DWG)
![]() | CB-016S2 .DWG File |
Power Source:
• 24VDC Battery or 24VDC Power Supply
• Battery or fullwave rectified with smoothed current <10% Ripple
• Battery or fullwave rectified with smoothed current <10% Ripple
Dimensions

Specifications
Electrical | • 24V DC ±10% input• 24VDC: Battery or fullwave rectified and smoothed current <10% Ripple
• Power ON delay <1s
• 4A locking current
• Input signal level for activation
• Output (error) signal
• Brake Model Only
| |
Brake | • Dynamic (Electric-Both models)
• Mechanical (CB-016S2B only)
| |
Protection | • Thermal protection reaction
• Built-in 5A fuse for line current to prevent overheating
• Built-in diode for incorrect wiring protection
| |
Terminal | • 2-Pole WAGO (CN1) | • 5-Pole WAGO (CN2) |
Motor Connector | • 9-Pole JST (CB0-16) | • 10-Pole JST (CB0-16B) |
Applicable Environment | • Temperature: 0 – 40° C (32 – 104° F) • Humidity: <90% Relative Humidity (no condensation) • Atmosphere: No corrosive gasses • Vibration: 0.5G |
Không có nhận xét nào: